This page lists the entity types exposed by the Dimplex Hub integration.

Entity names use Home Assistant’s has_entity_name pattern: the device is the appliance (or hub), and each entity has a short name such as “Room temperature” or “EcoStart”.

Climate

One climate entity per appliance.

Name Entity ID pattern Description
(device name) climate.<appliance> Thermostat: current room temperature, target setpoint, HVAC heat/off, presets. HVAC off is frost protection — the appliance has no off mode, only the 7 °C anti-freeze floor, which is exactly what the official app does.

Presets

A preset is a single, mutually exclusive state: selecting one engages what that preset owns and clears the others, so switching straight from away to eco works as you would expect. Why a preset cannot always show what the appliance is doing: Modes & presets.

Preset Behaviour
comfort Clears boost, away and EcoStart — follow the schedule.
boost Enables boost (default ~60 minutes, boost temperature when known).
away Enables away mode at the appliance away temperature when known, clamped to the 7-18 °C the cloud accepts for Away.
eco Enables EcoStart. This is the EcoStart pre-heat setting, not the cloud's separate Eco mode, which is unused.

Actions

  • climate.set_temperature — writes the target through the cloud's dedicated setpoint endpoint, so your schedule is left intact. Appliances that reject it fall back to a schedule rewrite. See setting a target.
  • climate.set_preset_mode — boost / away / eco / comfort.
  • climate.turn_on / climate.turn_off — off engages frost protection and clears boost/away; on clears it again. See why "off" reports 7 °C.
  • dimplex.set_advance / dimplex.clear_advance — skip forward to the next schedule period, bringing its setpoint on early.

Full field reference: Actions.

Climate (and most status entities) are unavailable when the cloud returns an empty appliance overview (common when heaters have not telemetered recently).

Sensors

Name Unit Device class Description
Room temperature °C temperature Current room temperature.
Target temperature °C temperature Active setpoint.
Boost temperature °C temperature Boost mode target.
Away temperature °C temperature Away mode target.
Setback temperature °C temperature Setback target.
Energy last 30 days kWh energy Rolling 30-day sum for register T1 only (off-peak / cheaper rate). No state class — not a meter, so it never enters long-term statistics. Translation key stays energy_lifetime.
Energy today kWh energy T1 (off-peak) kWh for the current local calendar day.
Energy T2 last 30 days kWh energy Rolling 30-day sum for register T2 only (peak / more expensive; disabled by default). No state class. Translation key stays energy_t2_lifetime.
Energy T2 today kWh energy T2 (peak) kWh for the current local calendar day (disabled by default).
Rated power kW power Static nameplate power from product provisioning (disabled by default).
Estimated power kW power Heuristic rated_power when boost or advance is engaged, else 0 (diagnostic, disabled by default; not a live meter).
Charge capacity kWh energy Static storage capacity from provisioning (disabled by default).
Error code Appliance error code (disabled by default).
Warning code Appliance warning code (disabled by default).
Last telemetry timestamp timestamp Last cloud telemetry time (disabled by default).
Hot water available The cloud's AvailableHotWater reading, for cylinders only (diagnostic, disabled by default; unit unconfirmed).

Energy attributes

Attribute Description
mode lifetime (the 30-day window) or daily.
register t1 or t2 (always separate).
window_days Days summed — 30 for the window sensors, 1 for today.
window_start / window_end Bounds of points used in the total.
telemetry_points Number of points included.

Energy data is daily kWh history from the cloud, not live watts. Sensors are unavailable (not 0) when there are no points, and T1 and T2 are never combined — they are separate dual-rate registers.

See Energy monitoring for adding these to the Energy Dashboard, the tariff mapping, and the automatic poll back-off when history stays empty.

Binary sensors

Name Device class Description
Comfort Comfort status from overview.
Open window window Open-window detection status (enabled flag from cloud).
Setback Setback mode active.
Connected connectivity Hub connection (one per hub).

The appliance mode bitfield is also broken out as four diagnostic binary sensors — Boost active, Away active, Frost protection, Advance active.

Name Mode bit Meaning
Boost active BOOST (2) A timed boost is running
Away active AWAY (4) Away setback is engaged
Advance active ADVANCE (16) The next schedule period was brought on early
Frost protection FROST_PROTECT (32) The 7 °C floor — what "off" means

These exist because the climate entity folds the whole bitfield into one preset, which is precisely what hid the mode mismatch behind #163: the integration asked for Boost and the heater engaged Advance, with nothing on the dashboard to say so.

Several bits can be set at once, so these four sensors can disagree with preset_mode — the sensors are the appliance's actual state and are the better thing to automate on. See Modes & presets for the whole model. A diagnostics download also lists the engaged modes by name.

Switches

Name Description
EcoStart Toggle EcoStart energy-saving mode.
Open window detection Enable/disable open-window detection (control; pairs with the binary sensor).

Numbers

Name Description
Setback target The reduced ("setback") temperature the appliance falls back to when setback mode is active. Writing it also marks the setback ACTIVE, which is what the official app's setback control does. Translation key setback_target.

Created only for appliances whose capability matrix says both setback_read and setback_write — a write that could never be read back would leave the entity showing a stale number forever. The Setback binary sensor reports whether setback is currently engaged, and the Setback temperature sensor reports the same value read-only.

The range offered is the capability matrix's own 7-30 °C. That range is inferred from the app rather than measured — see appliance support.

Schedule

Diagnostic Schedule sensor per appliance. Its state is the timer mode — manual, user_timer, frost_protection or off — and its periods attribute lists the programme as day / start / end / temperature.

The sensor is read-only. The programme can be copied to other appliances, and one period's target edited, through actions — see edit the weekly schedule.

Zones

Zone devices appear in the device registry (via hub; appliances via zone when zone id is known). A disabled diagnostic zone sensor anchors each zone device.

Automations

Worked examples using these entities live in Automations & blueprints. The diagnostic mode sensors are usually a better trigger than preset_mode, because the appliance can hold several modes at once while the preset can only report one.