Modes & presets

Almost everything confusing about this integration follows from one fact:

The appliance holds a set of modes, not one mode

ApplianceModes is a bitfield. Boost, away, advance, frost protection and several others are independent bits, and more than one can be set at the same time. Home Assistant's preset_mode is a single string, so it can only ever show one of them.

That mismatch is why #163 needed a decompiler to diagnose: the integration asked for boost, the appliance engaged advance, and the dashboard had no way to say so.

What the appliance reports

The full bitfield, as recovered from the official app. The integration reads four of these and ignores the rest.

Bit Value Mode Used by the integration
0 1 TIMER_MODE — following the schedule Implicitly, as "not overridden"
1 2 BOOST Boost active sensor, boost preset
2 4 AWAY Away active sensor, away preset
3 8 HOLIDAY No
4 16 ADVANCE Advance active sensor, dimplex.set_advance
5 32 FROST_PROTECT Frost protection sensor, HVAC off
6 64 ECO No — see eco is not Eco
7 128 MANUAL — holding one target, ignoring the schedule No
8 256 HYGIENE — hot water cylinder anti-legionella cycle No
9 512 STANDALONE No
10 1024 SAFE_MODE No
11 2048 SHUTDOWN No
12 4096 COMMS No
13 8192 NORMAL No
14 16384 STANDBY No

Before 4.1.0 these values were wrong

Earlier releases assumed boost was bit 16 and away bit 32. Those are in fact ADVANCE and FROST_PROTECT. Asking for boost engaged advance; asking for away engaged frost protection and pinned the heater to 7 °C. Both were corrected in 4.1.0 against the values above.

How it maps into Home Assistant

flowchart LR
    subgraph AP["Appliance — ApplianceModes bitfield"]
        direction TB
        B["BOOST (2)"]
        A["AWAY (4)"]
        AD["ADVANCE (16)"]
        F["FROST_PROTECT (32)"]
    end

    subgraph ES["Separate setting"]
        E["EcoStartEnabled"]
    end

    subgraph HA["Home Assistant"]
        direction TB
        HM["hvac_mode<br/>heat / off"]
        PM["preset_mode<br/>one value only"]
        BS["4 diagnostic sensors<br/>one per bit"]
    end

    F --> HM
    B --> PM
    A --> PM
    E --> PM
    B --> BS
    A --> BS
    AD --> BS
    F --> BS

    AD -. "not represented<br/>in preset_mode" .-> PM

The four diagnostic sensors are the lossless view. preset_mode is the convenient one.

Why preset_mode can disagree with reality

The entity resolves the bitfield to a single preset in a fixed order, and stops at the first match:

  1. Frost protection engaged, or the timer is in a frost/off mode → no preset, and hvac_mode is off
  2. BOOST set → boost
  3. AWAY set → away
  4. EcoStartEnabledeco
  5. Otherwise → comfort

So an appliance holding both boost and away reports boost, and one holding advance reports comfort — because advance has no preset of its own. Neither is a bug in the reporting; there is simply nowhere for the second value to go.

Automate on the diagnostic sensors, not on preset_mode, whenever you care about a specific mode:

triggers:
  - trigger: state
    entity_id: binary_sensor.living_room_advance_active
    to: "on"

Setting a preset clears the others

Home Assistant treats a preset as a single mutually exclusive state, so selecting one engages exactly what that preset owns and clears the rest.

Preset Engages Clears
comfort nothing — follow the schedule boost, away, EcoStart
boost boost away, EcoStart
away away boost, EcoStart
eco EcoStart boost, away

Clearing happens before engaging, so the appliance never briefly holds two conflicting modes.

Before 4.1.0 each preset only added its own state. Switching from away to eco enabled EcoStart but left away engaged, and because the resolution order above puts away ahead of EcoStart, the entity kept reporting away and nothing appeared to happen — that was #173.

Presets are also gated by appliance capability: one your appliance does not support is not offered in preset_modes and is skipped rather than sent blindly.

Temperature range per mode

The ranges genuinely differ, and only one is exposed as a climate limit.

Mode Range Notes
Normal setpoint 7–30 °C The climate entity's min_temp / max_temp
Boost 7–30 °C Believed the same; the app's picker offers it
Away 7–18 °C Genuinely lower. Higher values are clamped with a log warning
Advance 7–30 °C Or omit it and use the schedule's own target
Frost protection fixed 7 °C Not settable

Away is the one that surprises people: 18 is the ceiling in the official app's Away picker too, and the cloud silently reduces anything higher. See #174.

The non-Away ranges are inferred, not confirmed

7–30 °C for boost, advance and manual comes from reading the official app, not from testing each one. Since Away turned out to be an exception, the others are not fully trustworthy either. dimplex-controller-py#98 tracks re-reading each mode's range from the app.

Which modes stack

  • Frost protection wins over everything. It is the app's "off", and while it is engaged the integration reports hvac_mode: off and no preset, whatever else is set.
  • Boost and away can both be set at the appliance. The integration will not put them there — presets clear each other — but a change made in the official app can, and the diagnostic sensors will show it.
  • Advance stacks with anything. It affects the next schedule period, so it coexists with whatever is happening now.
  • EcoStart is orthogonal. It is a separate boolean, not a bit in this field, so it can be on alongside any mode.

Timer modes are a different field

TimerMode is a small enum, not part of the bitfield, and it says how the appliance treats its schedule:

Value Mode Meaning
0 USER_TIMER Follow the weekly programme — the normal state
1 MANUAL Hold one target, ignore the programme
2 FROST_PROTECTION The 7 °C floor
3 OFF Off

The integration exposes this as the diagnostic Schedule sensor, and treats modes 2 and 3 as "off" for hvac_mode, because that is how the official app presents them for most heaters. Turning a heater back on restores USER_TIMER for appliances an earlier release left parked in mode 2 or 3.

"Off" is frost protection

There is no off mode. Turning a Dimplex appliance off, in the official app or here, engages frost protection at 7 °C — an anti-freeze floor that stops rooms and pipework freezing.

So after climate.turn_off the entity reports a 7 °C target, hvac_mode: off and hvac_action: off. That is correct. Full detail in why "off" reports 7 °C.

The eco preset is not Eco mode

Two different things share the name, and the integration uses only one of them.

EcoStartEnabled ECO (bit 64)
What A pre-heat setting An appliance mode
Does Learns the room's warm-up time and starts early so target is met on time Unknown — never tested
Exposed as The eco preset, the EcoStart switch, dimplex.set_eco_start Nothing

The eco preset drives EcoStart. The cloud's separate Eco mode bit is read but never written and has no entity, because its behaviour on real hardware has not been established.

This ambiguity is worth knowing about precisely because the new mode sensors sit next to a preset called eco that has nothing to do with the ECO bit.

Seeing the real state

Three ways, in increasing detail:

  1. The four diagnostic binary sensors — boost, away, frost protection, advance. Disabled by default; enable them in the entity registry.
  2. A diagnostics download — decodes ApplianceModes into mode names, so you do not have to do the arithmetic. See diagnostics & bug reports.
  3. The raw valueApplianceModes appears in diagnostics as an integer. 8198 is BOOST | AWAY | NORMAL (2 + 4 + 8192)… which is exactly the sort of sum nobody should have to do by hand, hence the decoding above.